DFM Platform
DFM Funding Monitor

DDG-MRI for cancer detection - A novel medical imaging approach that correlates to FDG-PET without ionising radiationbroad

DDG-MRI · Horizon Europe grant · 2024-12-01–2027-11-30

EC contribution

€2,991,061

Total cost

€2,991,061

Beneficiaries

7
About the data

Source: CORDIS (official EU open data), Horizon Europe. Framework HORIZON · call HORIZON-EIC-2024-PATHFINDEROPEN-01 · scheme HORIZON-EIC · topic HORIZON-EIC-2024-PATHFINDEROPEN-01-01. CORDIS record →

Objective

Positron emission tomography (PET) measurements of 2-deoxy-2-[18F]fluoro-D-glucose (FDG) uptake have been widely used clinically for tumour staging, prognosis, and treatment monitoring, where it can be more sensitive at detecting treatment response than magnetic resonance imaging (MRI) and computerised tomography (CT) -based evaluations of tumour size. 2-deoxy-D-glucose (DG) and FDG are non-metabolisable derivatives of D-glucose that get trapped in the cells of active or malignant tissues. Even though highly sensitive, the ionising radiation associated with FDG-PET limits its frequent application (typically not more than 2-3 examinations per year) and its use in populations such as children and pregnant women, who may otherwise benefit from this valuable and unique diagnostic imaging examination. As such, alternative techniques are highly demanded. The DDG-MRI project aims at providing the benefits of FDG-PET without ionising radiation. We propose an MRI-based imaging agent and technique that will provide PET-like images with MRI without ionising radiation. To this end, we will make use of 1) a novel DG analogue that is uniformly labelled with deuterons ([D8]2-deoxy-D-glucose) and 2) rapid and sensitive deuterium MRI schemes targeted at demonstrating the uptake of this agent in malignant tissues further to intravenous administration. The expected spatial resolution will exceed that of FDG-PET (~2-3 mm in plane) in a scan time of about 2 min, with a clinically acceptable and commercially relevant dose of the labelled compound. DDG-MRI is likely to be quickly adopted by medical centres as it does not require significant hardware changes, does not change the MRI suite workflow, and is expected to cost the same as a PET scan. This consortium comprises six partners (two from industry) from five countries, enthusiastic about making DDG-MRI a medical reality for cancer detection and treatment monitoring.

Beneficiaries (7)

OrganisationCountryRoleEC contributionSME
HADASSAH MEDICAL ORGANIZATION IL coordinator €500,000
GE HEALTHCARE LIMITED UK participant €500,012
CORTECNET FR participant €500,000 Yes
UNIVERSITA DEGLI STUDI DI TORINO IT participant €499,676
UNIVERSITAET ULM DE participant €496,875
DANMARKS TEKNISKE UNIVERSITET DK participant €494,498
GE HEALTHCARE GMBH DE thirdParty €0

Get the DFM funding briefing — free

New EU defence calls, tenders and awards in your inbox.

Countries
Sectors
Sources

We store your email only to send the DFM briefing/alerts and to add you to DFM Analysis. Unsubscribe anytime.

Defence Finance Monitor is an analytical and informational product. Grant data is official CORDIS; payment and subscription happen on DFM Analysis.